As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FS 589, LBL 9 - LBL 27, FLOORBEAM ANGLE CORRODED. REMOVED FLOOR SUPPORT ANGLE IAW SRM 51-40-11. REQUIRE INSTALLATION. FLOOR SUPPORT ANGLE CORROSION IS OUT OF LIMIT OF THE ALLOWABLE DAMAGE IAW SRM 53-00-00. LOCATED AND DRILLED UP NEW FLOOR CAP STRIP PN 601R35031-165 IAW SRM 51-42-06, 51-42-21. INSTALLED NEW FLOOR CAP STRIP PN 601R35031-165 IAW SRM 51-42-06, 51-42-21. INSTALLED MYLAR TAPE ONTO THE FLOOR SUPPORT ANGLE AT FS 589 LBL 9-LBL 22 IAW SRM 51-27-19.