What was found
FOUND FS 409+128 BL 0.0 RT SIDE VERTICAL POST HAS INDICATION NOTED APPROX .2" IN LENGTH 50 PERCENT FSH. FAILED NDT INSP (WL 69.0 AFT FLANGE RADIUS). REMOVED POST FS 409+128 BL 0 IAW SRM 51-42-06, 51-42-21. LOCATED AND DRILLED UP NEW FS 409+128 BL 0 VERTICAL POST IAW SRM 51-40-11. INSTALLED VERTICAL POST AT FS 409+128 BL 0 IAW REO 601R-53-41-889. C/W EC/TC REO 601R-53-41-889 AND MET ALL THE REQUIREMENTS OF REO 601R-53-41-889 REV A.