What was found
INTERCOSTAL AT FS 559+112, BETWEEN RBL 36 AND FLOOR SUPPORT SILL IS CORRODED. FOUND DAMAGE TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-51-43. FURTHER INESTIGATION OF CORROSION AT FS 559.00+112 BETWEEN RBL 36 AND FLOOR SILL, FOUND CORROSION TO BE MINOR SURFACE CORROSION ON CAP STRIP. REMOVED CAP STRIP IAW SRM 51-42-06 AD 51-42-10. REMOVED SURFACE CORROSION IAW SRM 51-21-6. DEPTH OF MATERIAL REMOVED WAS .003" WHICH IS WITHIN ALLOWABLE DAMAGE LIMITS OF SRM 53-00-00. ALODINED, PRIMED AND PAINTED CAP STRIP IAW SRM 51-25-06 AND 51-25-16. INSTALLED CAP STRIP IAW SRM 51-42-06 AND 51-42-10. APPLIED CORROSION INHIBITOR TO ALL AREAS IAW SRM 51-21-11.