What was found
INTERCOSTAL AT FS 589, RBL 36 AND FLOOR SUPPORT SILL IS CORRODED. FOUND FLOOR SUPPORT SILL TO BE CORRODED OUT OF ALLOWABLE LIMITS IAW SRM 53-61-43. REMOVED CAP STRIP AT FS 589.00, INTERCOSTAL RBL 36 FLOOR SUPPORT IAW SRM 51-42-06 AND 51-42-10. UPON FURTHER INVESTIGATION OF DAMAGE AT FS 589.00 BETWEEN RBL 36 AND FLOOR SILL THE DAMAGE WAS SURFACE CORROSION ON CAP STRIP. REMOVED SURFACE CORROSION IAW SRM 51-21-06. DEPTH DAMAGE REMOVED WAS .004"" DEEP AND IS WITHIN ALLOWABLE DAMAGE LIMITS OF SRM 53-00-00. ALODINE, PRIMED AND TOP COATED CAP STRIP IAW SRM 51-25-06 AND 51-25-16. INSTALLED CAP STRIP IAW SRM 51-42-06 AND 51-42-10.