Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
September 2, 2010
Submitted
September 3, 2010
Operation
Air carrier
Aircraft
N823AS
Make and model
Cndair CL6002B19
Aircraft serial
7196
Aircraft time
29,658 hours, 26,752 cycles
Part
Floor Support
Condition
Corroded
Location
Bs 559-621
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLOOR SUPPORT OTBD OF RBL 36 IS CORRODED FROM FS 621.00 TO FS 559.00+80. FOUND FLOOR SUPPORT TO BE CORRODED BEYOND ALLOWABLE LIMITS IAW SRM 53-61-43. REMOVED NUTLATES FROM FLOOR SILL BETWEEN FS 559+80 TO FS 621 IAW SRM 51-42-01. COMPLIED WITH STEP 1 OF REO 601R-53-00-383. STEPS 2-5 OF REO REQUIRE COMPLETION AND NUTPLATES INSTALLED. RT SIDE SILL AT NUTPLATE HOLE LOCATED AT FS 578.00 WAS OUT OF LIMITS OF REO 601R-53-00-383. REF MWC JOB 8719631 OP 524 FOR REPAIR. COMPLIED WITH STEP 3 OF REO 601R-53-00-383. PERFORMED EDDY CURRENT. NO INDICATIONS NOTED. COMPLIED WIITH STEPS 2, 4 AND 5 OF REO 601R-53-00-383. REO 601R-53-00-383 HAS BEEN ACCOMPLISHED.