What was found
FRAME AT BS 409+16 IS CORRODED FROM S27-26R. REMOVED FS 409+16 FRAME SECTOR FROM S21L-21R IAW SRM 51-42-06. LOCATED, DRILLED AND DEBURRED NEW FRAME IAW SRM 51-40-11. CUT FRAME AT STA 333 BETWEEN S26R & 25R IAW SRM 53-00-15. COMPLIED WITH SRM 53-00-15. PERFORMED EDDY CURRENT OF FRAME CUT LINES IAW NDTM 51-20-06. NO INDICATIONS NOTED. FABRICATED REPAIR SPLICES PER SRM 53-00-15. PERFORMED HEAT TREAT ON FABRICATED REPAIR SPLICES FROM 7075-0 .050 TO T62 IAW SRM 51-24-06. COMPLIED WITH SRM 53-00-15, PERFORMED LPI OF FABRICATED PARTS IAW NDTM 51-20-80. NO INDICATIONS NOTED. INSTALLED ALL REPAIR PARTS IAW SRM 53-00-15 STEPS 7-10, PAINTED SRM 51-25-16.