What was found
FS 409+32 SECTOR CORRODED FROM STR 25L TO 25R. REMOVED FASTENERS AND CUT FRAME AT S25R AND 25L IAW SRM 51-00-15. C/W SRM 53-00-15 REPAIR 1 STEP 5, A6. PERFORMED EDDY CURRENT OF FRAME CUT LINES IAW NDTM 51-20-06. NO INDICATIONS NOTED. FABRICATED REPAIR SPLICE AND DOUBLERS FROM NEW ORIGINAL FRAME IAW SRM 53-00-15 ITEM 8. INSTALLED ALL PARTS COMMON TO FS 409+32 SPLICE REPAIR IAW SRM ITEM 15 & 16. PAINTED REPAIRED AREA IAW SRM 51-25-01 AND APPLIED WATER DISPLACING CORROSION INHIBITING COMPOUND IAW SRM 51-21-11.