What was found
FS 559.00 SEMI-PRESSURE BULKHEAD WEB FAILED NDT INSP IN 3 LOCATIONS: 1 IN WEB AT WL 59.0 INBD OF POST AT RBL 18, 1 IN WEB AT WL 58.7-59.1 OTBD OF POST AT RBL 9.0, 1 IN WEB AT WL 51.7 OTBD OF POST AT LBL 9.0. CRACK INDICATIONS ARE APPROX .05"-.30" LONG AND OVER 50 PERCENT FSH. REPAIRED FS 559 BULKHEAD CAP ANGLES AND WEBS FROM LBL 27 TO RBL 27 IAW REO 601R-53-41-260 REV E, STEPS 1 THRU 14. C/W EC/TC REO 601R-53-41-260 AND REO 601R-53-41-260 REV E, DATED AS WRITTEN.