What was found
BUTT STRAP AT FS 333, STR 25-27L HAS CORROSION. REMOVED FASTENERS COMMON TO CORRODED AREA. BLENDED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-31, FIG 103. REMOVED REMAINING FASTENERS COMMONG TO CUT SPLICE STEP 23L-STR 23R IAW SRM 51-42-06. DRILLED UP NEW BUTT STRAP IAW SRM 51-42-06. OK TO INSTALL. INSTALLED BUTT STRAP AND RESECURED STR 27 IAW SRM 51-42-06. RESECURE REMAINING STRS 26R, 25L,R, AND 24L,R AND SEAL GAP. INSTALLED REMAINING RIVETS MISSING FROM STR 26R, 25L&R AND 24L&R IAW SRM 51-42-06. PAINTED AND GAP SEALED REPAIRED AREA AT FS 333 STR 25L-STR 27 IAW SRM 51-23-00 AND 51-25-01.