What was found
STRINGER 27 CORRODED BETWEEN FS 319.00 AND FS 349.00. CUT STRINGER 27 AT FS 325 AND REMOVED AFT CORRODED SECTION IAW REO 601R-53-21-1183 REV & SRM 53-00-03. CUT EDGES OF STR 27 AFT FS 325. COMPLIED WITH SRM 53-00-03. PERFORMED EDDY CURRENT OF CUT EDGES IAW NDTM 51-20-06. NO INDICATIONS NOTED AT THIS TIME. SPLICED IN NEW STRINGER FS 325 TO FS 364 IAW REO 601R-53-21-1183 REV. AND SRM 53-00-03. PAINTED FASTENER HEADS IAW SRM 51-25-01. REO 601R-53-21-1183 HAS BEEN ACCOMPLISHED AND ALL STEPS HAVE BEEN DOCUMENTED AND SIGNED FOR ON A NRI CARD. ALL RII'S HAVE BEEN ACCOMPLISHED IAW GMM 3-3 PROCEDURES, PRIOR TO THE ACFT BEING RETURNED OT SERVICE.