What was found
INTERCOSTAL AT FS 559.00+80 BETWEEN RBL 9 AND RBL 27 IS CORRODED. REMOVED CAP STRIP AT FS 559.00+80 INTERCOSTAL BETWEEN RBL 9-27 IAW SRM 51-42-06 AND 51-42-10. AFTER FURTHER INVESTIGATION OF DAMAGE AT FS 559.00+80 BETWEEN RBL 9 AND RBL 27, FOUND DAMAGE TO BE SURFACE CORROSION ON CAP STRIP. REMOVED THE SURFACE CORROSION IAW SRM 51-21-06. DEPTH OF DAMAGE REMOVAL WAS .008" DEEP AND IS WITHIN ALLOWABLE DAMAGE LIMITS OF SRM 53-00-00. ALODINED, PRIMED AND TOPCOATED CAP STRIP IAW SRM 51-25-06 & 51-25-10. INSTALLED CAP STRIP IAW SRM 51-42-06 AND 51-42-10.