What was found
CLIP ON FWD SIDE OF FLOOR SUPPORT CROSSMEMBER AT FS 349, RBL 42 IS CORRODED. REMOVED FWD CLIP IAW SRM 51-42-06 AND 51-42-21. LOCATED AND INSTALLED SERVICEABLE CLIP AT FS 349, RBL 42 IAW SRM 51-42-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLIP ON FWD SIDE OF FLOOR SUPPORT CROSSMEMBER AT FS 349, RBL 42 IS CORRODED. REMOVED FWD CLIP IAW SRM 51-42-06 AND 51-42-21. LOCATED AND INSTALLED SERVICEABLE CLIP AT FS 349, RBL 42 IAW SRM 51-42-06.