What was found
CONTINUATION OF MWC 347. FLOOR SUPPORT OTBD OF RBL 36 IS CORRODED FROM FS 621.00 TO FS 559.00+80. 26 EA NUTPLATES NEED INSTALLED. REINSTALLED 26 EA NUTPLATES IAW SRM 51-42-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CONTINUATION OF MWC 347. FLOOR SUPPORT OTBD OF RBL 36 IS CORRODED FROM FS 621.00 TO FS 559.00+80. 26 EA NUTPLATES NEED INSTALLED. REINSTALLED 26 EA NUTPLATES IAW SRM 51-42-10.