What was found
FS 280, RBL 9 OTBD FLOOR SUPPORT CLIP CRACKED. REMOVED CLIP & EXISTING SHIM. FABRICATED A NEW CLIP, TREATED, PIRMED AND PAINTED, SEALED AND INSTALLED THE SAME SERVICEABLE SHIM AND NEW CLIP. PRIMED AND PAINTED AFTER INSTALLATION. ALL WORK PERFORMED IAW ASA REO 601R-53-11-926 IAW REO 601R-53-11-926, REV B. COMPLIED WITH EC/TC REO 601R-53-11-926 IAW REO 601R-53-11926, REV B.