What was found
CORROSION AROUND SEVERAL SCREW HOLES UNDER FLOORBOARD 251ALF AND ON FLOORBEAMS. BLENDED CORROSSION ON FLOORBEAM. PERFORMED UT THICKNESS INSP OF BLEND AREAS IAW MAC NOT INSP PROCEDURE UT-3. FOUND TO BE IN LIMITS IAW REO 601R-53-00-005.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AROUND SEVERAL SCREW HOLES UNDER FLOORBOARD 251ALF AND ON FLOORBEAMS. BLENDED CORROSSION ON FLOORBEAM. PERFORMED UT THICKNESS INSP OF BLEND AREAS IAW MAC NOT INSP PROCEDURE UT-3. FOUND TO BE IN LIMITS IAW REO 601R-53-00-005.