Service difficulty report · Floorbeam · Cndair CL6002B19

Difficulty date
December 8, 2010
Submitted
December 10, 2010
Operation
Air carrier
Aircraft
N867AS
Make and model
Cndair CL6002B19
Aircraft serial
7463
Aircraft time
23,610 hours, 20,492 cycles
Part
Floorbeam
Condition
Corroded
Location
Bs 559
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLOORBOARD SUPPORT STRAPS AT FS 559.00, RBL 27.00 TO RBL 36.00 AND LBL 27.00 TO 36.00 ARE CORRODED. REMOVED CORROSION FROM STRAPS IAW 51-21-06, STEP 3. TREATED, PRIMED AND TOPCOATED BOTH AREAS IAW SRM 51-21-11, 51-25-06, 51-25-16. MATERIAL THICKNESS FOR BOTH FLOORBOARD SUPPORT STRAPS IS .050 IAW SRM 53-41-43. MATERIAL LOSS FOR BOTH IS .003, REMAINING MATERIAL IS .047. BOTH STRAPS FOUND TO BE IN LIMITS IAW SRM 53-00-00. THIS REPAIR IS CLASSIFIED AS A MINOR REPAIR IAW SOP 5702.