What was found
FLOOR SUPPORT HAS MINOR CORROSION AROUND SCREW HOLES AT LBL 27 FROM FS 589.00 TO 621.00. REMOVED CORROSION FROM FLOORBEAM IAW SRM 51-21-06 BEAM IS OUT OF LIMITS IAW 53-00-00. REMOVED FLOOR SUPPORT CAP FROM LBL 27, FS 574.00-FS 620.00. ALL WORK DONE IAW SRM 51-42-06 AND 51-42-21. INSTALLED NEW FLOOR SUPPORT CAP IAW REO 601R-53-61-3778. APPLIED FINISH TO AREA AND CIC IAW SRM 51-25-16, 51-21-11 AND REO 601R-53-61-3778, FOUND TO BE SATISFACTORY.