What was found
LT PRESSURE FLOOR SKIN OTBD OF LBL 36 IS CORRODED AT FS 461. REMOVED CORROSION ON RT PRESSURE FLOOR SKIN ASSY IAW REO 601R-53-41-666. REF MATERIAL LOSS FOR PRESSURE FLOOR SILL ASSY ANGLE WAS .010 FROM PREVIOUS BLENDOUT. REMOVED .002 MORE MATERIAL MAKING .012 TOTAL MATERIAL LOSS. REMAINING MATERIAL IS .068. MINIMUM ALLOWABLE MATERIAL THICKNESS IS .055 IAW REO 601R-53-41-666. AREA FOUND IN LIMITS IAW REO 601R-53-41-666. TREATED, PRIMED AND TOPCOATED AREA IAW REO 601R-53-41-666. PERFORMED EDDY CURRENT OF RT FLOOR SKIN REPAIRED AREAS IAW NDTM 51-20-06. NO INDICATIONS NOTED AT THIS TIME. APPLIED CIC IAW REO 601R-53-41-666, 2-2 DISPOSITION, STEP F.