What was found
RT PRESSURE FLOOR CORRODED AT SEVERAL LOCATION BETWEEN FS 409 AND 559. PERFORMED UT THICKNESS INSPECTION OF BLEND AREAS IAW MAC NDT INSPECTION PROCEDURE UT-3. BLENDS AREAS ARE WITHIN ALLOWABLE LIMITS OF REO 601R-53-41-666 TABLE 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT PRESSURE FLOOR CORRODED AT SEVERAL LOCATION BETWEEN FS 409 AND 559. PERFORMED UT THICKNESS INSPECTION OF BLEND AREAS IAW MAC NDT INSPECTION PROCEDURE UT-3. BLENDS AREAS ARE WITHIN ALLOWABLE LIMITS OF REO 601R-53-41-666 TABLE 2.