Service difficulty report · Floorbeam · Cndair CL6002C10

Difficulty date
February 3, 2011
Submitted
February 18, 2011
Operation
Air carrier
Aircraft
N717EV
Make and model
Cndair CL6002C10
Aircraft serial
10088
Aircraft time
20,416 hours, 14,070 cycles
Part
Floorbeam
Condition
Corroded
Location
Bs 280
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

REMOVED COCKPIT FLOOR SUPPORT BEAM FROM FS280, FLOOR SUPPORT BEAM. REMOVED COCKPIT FLOOR SUPPORT BEAM FROM FWD SIDE OF 280 CROSSBEAM IAW SRM 51-42-06-001-001-A01, 51-42-27-001-001-A01 AND 51-42-22-001-001-A01. INSTALLED COCKPIT FLOOR SUPPORT BEAM ON FWD SIDE OF 280 CROSSBEAM IAW SRM 51-42-06-001-001-A01 AND 51-42-20-001-001-A01. COCKPIT FLOOR SUPPORT BEAM CORRODED OUT OF REPAIRABLE LIMITS. DRILLED NEW COCKPIT FLOORBEAM IAW SRM 51-40-11-001-001-A01. INSTALL NEW COCKPIT FLOORBEAM. INSTALLED COCKPIT FLOOR PANEL ANGLE PN CC670-33292-135 IAW SRM 51-42-06-001-001-A01 AND 51-42-20-001-001-A01. INSTALL 2 EA CAMLOCKS. INSTALLED 2EA CAMLOCKS ON COCKPIT FLOOR PANELS IAW SPM 51-42-06-001-001-A01. DS 80077 2/8/11 (HF 161797 2/14/11) ASA RII MAC NR 3QC BD 5500008 2/9/11, RII FOUND TO BE SATISFACTORY. (CLOSED)