What was found
DURING REPLACEMENT OF PAX DOOR AFT WEB STIFFENER, FOUND AFT WEB CRACKED AT 3 LOCATIONS ZONES 2, 3 AND 4. COMPLIED WITH STEPS 1-10 AND 13-19 OF REO 601R-52-11-702 REV C. COMPLIED WITH STEPS 11 AND 12 ON REO 601R-52-11-702. COMPLIED WITH EC/TC REO 601R-52-11-702 AND MET ALL REQUIREMENTS OF REO 601R-52-11-702 REV C.