What was found
FLOORBEAM & CAP ARE CORRODED AT FS 349 BETWEEN RBL 27 & RBL 45. FOUND OUT OF LIMITS IAW SRM 53-00-00, FIG 101, SHT 3. REPAIRED IAW REO 601R-53-21-1262.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM & CAP ARE CORRODED AT FS 349 BETWEEN RBL 27 & RBL 45. FOUND OUT OF LIMITS IAW SRM 53-00-00, FIG 101, SHT 3. REPAIRED IAW REO 601R-53-21-1262.