What was found
ISOLATOR BROKEN ON FWD FACE OF 621 BULKHEAD APPROX 20" ABOVE FLOOR AT LBL 9 AND RBL 9. R & R ISOLATOR FWD FACE 621 BULKHEAD LBL 9 AND RBL 9 IAW SRM 51-42-06. THIS REPAIR IS CLASSIFIED AS A MINOR REPAIR IAW SOP 5702.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ISOLATOR BROKEN ON FWD FACE OF 621 BULKHEAD APPROX 20" ABOVE FLOOR AT LBL 9 AND RBL 9. R & R ISOLATOR FWD FACE 621 BULKHEAD LBL 9 AND RBL 9 IAW SRM 51-42-06. THIS REPAIR IS CLASSIFIED AS A MINOR REPAIR IAW SOP 5702.