What was found
621 BULKHEAD VERTICAL STIFFENER AT BL 0 IS CHAFED APPROX 1" L X .5" W X .005 ABOVE ESB. BLENDED AREA ON FS 621 BL 0.02 MEMBER IAW REO 601R-53-61-1523. PERFORMED EDDY CURRENT INSP ON THE NEWLY BLENDED AREA OF THE VERTICAL STIFFENER AT FS 621, BL0.0. NO INDICATIONS FOUND AT THIS TIME IAW ITEM 4 OF REO 601R-53-61-1523 AND NDTM PART 1, 51-20-06. TREATED & RESTORED FINISH TO REPAIRED AREA ON 621 BULKHEAD VERT STIFFENER AT BL 0 IAW REO 610R-53-61-1523, STEP 3. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW SOP 5702.