What was found
FLOOR SUPPORT INTERCOASTAL J-ANGLE CORRODED AT FS 349, RBL 45. REMOVED ANGLE IAW SRM 51-41-06, 5142-01 AND 51-41-02. FOUND ANGLE TO BE CORRODED BEYOND REPAIRABLE LIMITS IAW 53-00-00. REPAIRED IAW REO 601R-53-21-1290.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT INTERCOASTAL J-ANGLE CORRODED AT FS 349, RBL 45. REMOVED ANGLE IAW SRM 51-41-06, 5142-01 AND 51-41-02. FOUND ANGLE TO BE CORRODED BEYOND REPAIRABLE LIMITS IAW 53-00-00. REPAIRED IAW REO 601R-53-21-1290.