As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PAX DOOR LOWER SILL UPPER ANGLE CORRODED AROUND RIVETS ATTACHING LIGHTNING PROTECTION MOUNTING CLIPS. AFTER FURTHER INVESTIGATION FOUND PROTECTOR LEAD CONNECTION ANGLE TO BE CORRODED ONLY, ANGLE IS IN SERVICEABLE CONDITION WITH NO CORROSION EVIDENT WHATSOEVER. ANGLE WAS CLEANED IAW SRM 51-26-00. FASTENERS WERE REPLACED IAW SRM 51-42-11 AND 51-42-13. MINOR REPAIR.