What was found
CRACK ON FLOOR IN LT FWD EQUIPMENT COMPARTMENT ADJACENT TO BRAKE ACCUMULATOR GAUGES. PERFORMED EDDY CURRENT INSP OF CUTLINE AND UNDERLYING STRUCTURE IAW REO 670-53-11-509 NDTM PART 1. NO INDICATIONS NOTED AT THIS TIME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON FLOOR IN LT FWD EQUIPMENT COMPARTMENT ADJACENT TO BRAKE ACCUMULATOR GAUGES. PERFORMED EDDY CURRENT INSP OF CUTLINE AND UNDERLYING STRUCTURE IAW REO 670-53-11-509 NDTM PART 1. NO INDICATIONS NOTED AT THIS TIME.