What was found
FLOORBEAM CAP AT LBL 9 HAS CORROSION AROUND SEVERAL NUTPLATES BETWEEN FS 574 AND 619. REMOVED FLOORBEAM CAP IAW SRM 51-42-06 AND SRM 51-42-21. LOCATED AND DRILLED NEW CAP IAW SRM 51-40-11. INSTALLED NEW CAP IAW REO 601R-53-61-3780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM CAP AT LBL 9 HAS CORROSION AROUND SEVERAL NUTPLATES BETWEEN FS 574 AND 619. REMOVED FLOORBEAM CAP IAW SRM 51-42-06 AND SRM 51-42-21. LOCATED AND DRILLED NEW CAP IAW SRM 51-40-11. INSTALLED NEW CAP IAW REO 601R-53-61-3780.