What was found
FS 349 TO TRANSVERSE BEAM ATTACHMENT FITTING HAS 2 SPOTS OF MINOR CORROSION AT UPPER INBD END, WORST AREA MEASURES APPROX .4" LONG X .20" WIDE X .003" DEEP. REMOVED THE FS 349, LBL 45 TRANSVERSE BEAM ATTACH FITTING IAW SRM 51-42-21. FOUND CORROSION DAMAGE TO BE OUT OF LIMITS IAW SRM 53-21-23 & 53-00-00. PERFORMED STEP 3 OF REO EDDY CURRENT REPAIRED AREAS, NO INDICATIONS NOTED. ROTOPEENED REWORKED AREAS IAW SRM 51-24-11. INSTALLED FITTING AT FS 349, LBL 45 IAW SRM 51-42-21.