As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM CAP AT RBL 27 HAS CORROSION AROUND SEVERAL NUTPLATES BETWEEN FS 589 & FS 619. REO 601R-53-61-4125 HAS BEEN ACCOMPLISHED AND ALL STEPS HAVE BEEN DOCUMENTED AND SIGNED FOR ON A NON-ROUTINE WORK CARD. ALL RII'S HAVE BEEN ACCOMPLISHED BY A TRAINED, QUALIFIED AND AUTHORIZED RII INSPECTOR GMM 3-3 PROCEDURES, PRIOR TO THE ACFT BEING RETURNED TO SERVICE. RII FOUND TO BE SATISFACTORY. (CLOSED)