As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR-LEVEL EMERGENCY FLOOD LIGHT LOCATED ON WARDROBE IS INOPERATIVE. REMOVED & INSTALLED SERVICEABLE EMERGENCY FLOODLIGHT IAW AMM 33-51-19-400-801. EMERGENCY FLOODLIGHT STILL INOPERATIVE. INVESTIGATED SYS IAW WDM 35-51-00 & DETERMINED NR 2 BATTERY PACK CHARGER ASSY TO BE FAULTY. R & R CHARGER & BATTERY ASSY IAW AMM 33-51-05-400-801 & 33-31-04-400-801. OPS TEST GOOD AT THIS TIME.