What was found
FS 621 BULKHEAD FLOOR SUPPORT ANGLE HAS LIGHT CORROSION FROM RBL 27-RBL 45. FOUND CORROSION TO BE PITTED AT AND AROUND FASTENER HOLES AT FS 621, RBL 27- RBL 45. AREA FOUND OUT OF LIMITS IAW SRM 51-21-06. ACCOMPLISHED STEP 1 OF REO 601R-53-61-4166. MAX MAT LOSS .004. COMPLIED WITH STEP 3 OF REO 601R-53-61-4166. PERFORMED EDDY CURRENT OF FLOOR SUPPORT REPAIR IAW NDTM 51-20-06. NO INDICATIONS NOTED. ACCOMPLISHED STEPS 2, 4, 5 AND 6 OF REO 601R-53-61-4166. REO 601R-53-61-4166 REV-- HAS BEEN ACCOMPLISHED