As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RBL 27 FLOOR SUPPORT HAS LIGHT CORROSION AROUND NUTPLATES FROM FS 574-619. UPON REMOVAL OF CORROSION DAMAGE, FOUND BEYOND LIMITS IAW REO 601R-53-00-005. R & R FLOOR SUPPORT WITH NEW SERVICEABLE PIECE IAW SRM 51-42-21 AND 51-42-22 AND REO 601R-53-61-4174.