What was found
FLOORBEAM CAP CORRODED AROUND NUTPLATE HOLES AT FS 589 BETWEEN LBL 9 AND LBL 27. R & R DAMAGED TEE CAP WITH NEW CAP IAW SRM 51-40-11 STEP 11, SRM 51-42-06 STEP 9 AND SRM 51-42-21 STEPS 9, 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM CAP CORRODED AROUND NUTPLATE HOLES AT FS 589 BETWEEN LBL 9 AND LBL 27. R & R DAMAGED TEE CAP WITH NEW CAP IAW SRM 51-40-11 STEP 11, SRM 51-42-06 STEP 9 AND SRM 51-42-21 STEPS 9, 11.