What was found
FLOOR LEVEL EMERGENCY LIGHT BY MAIN DOOR COVER MISSING. R & R EMERGENCY FLOOR LEVEL LIGHTING COVER IAW AMM 33-51-19. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR LEVEL EMERGENCY LIGHT BY MAIN DOOR COVER MISSING. R & R EMERGENCY FLOOR LEVEL LIGHTING COVER IAW AMM 33-51-19. OPS CHECK GOOD.