As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT SILL AT RBL 36 IS CORRODED BETWEEN 559+96 AND 559+112. C/W STEPS 4 & 5 OF REO 601R-53-51-175. ECTC REQ'D. MFG ISSUED REV 601R-53-51-175, REV--, DATED 10/24/11 HAS BEEN ACCOMPLISHED AND ALL STEPS HAVE BEEN DOCUMENTED AND SIGNED FOR ON A NON-ROUTINE WORK CARD. ALL RII'S HAVE BEEN ACCOMPLISHED BY A TRAINED, QUALIFIED AND AUTHORIZED RII INSPECTOR GMM 3-3 PROCEDURES, PRIOR TO THE ACFT BEING RETURNED TO SERVICE. RII FOUND TO BE SATISFACTORY. (SDR CLOSED)