What was found
FS 460 SUPPORT ON OTBD SIDE OF RBL 9 PRESSURE FLOORBEAM IS CRACKED. REMOVED CRACKED SUPPORT FITTING IAW SRM 51-42-06, 51-42-21 & 51-40-11. INSTALLED NEW SUPPORT IAW SRM 51-42-06 & 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 460 SUPPORT ON OTBD SIDE OF RBL 9 PRESSURE FLOORBEAM IS CRACKED. REMOVED CRACKED SUPPORT FITTING IAW SRM 51-42-06, 51-42-21 & 51-40-11. INSTALLED NEW SUPPORT IAW SRM 51-42-06 & 51-42-21.