What was found
CARGO COMPARTMENT RT FLOOR SILL UPPER SURFACE BEWTEEN SURFACE BETWEEN FS 574.00+86 AND 559.00+112 AROUND FASTENER HOLES CORRODED. REMOVED CORROSION IAW SRM 51-21-06. PERFORMED UT THICKNESS OF BLEND AREA IAW MAC NDT INSPECTION PROCEDURE UT-3. MIN MATERIAL REMAINING IS .061" ORIGINAL IS .063" MATERIAL REMOVED IS .002". BLEND AREA WITHIN ALLOWABLE LIMITS IAW SRM 53-00-00, FIG 102, SHEET 2. RESTORED FINISH IAW SRM 51-25-06, 51-26-16, 51-21-11.