What was found
PILOT WINDSHIELD SIDE POST LOWER AFT SUPPORT BRACKET CRACKED. RECONNECTED LT WINDSHIELD HEATER POWER TERMINAL BLOCK WIRES IAW AMM 56-11-01-400-801. DISLODGED PILOT'S SIDE INSTRUMENT PANEL FOR ACCESS IAW SRM 51-44-00 AND 51-44-06. INSTALLED INSTRUMENT PANEL IAW SRM 51-44-10 & 51-44-06. REMOVED AFT LOWER WINDSHIELD POST BRACKET FOR REPLACEMENT IAW SRM 51-42-21. INSTALLED NEW WINDSHIELD POST BRACKET IAW SRM 51-42-21. THIS REPAIR REQUIRES MAJOR/MINOR CLASSIFICATION IAW ASA SOP 5702. THIS REPAIR IS CLASSIFIED AS A MINOR REPAIR IAW ASA SOP 5702. AFT LOWER WINDSHIELD POST BRACKET REQUIRES PRIMER AND DINITROL. APPLIED PRIMER TO WINDSHIELD POST BRACKET IAW SRM 51-25-06 AND DYNATROL IAW SRM 51-21-11. OPS TET OF THE WINDSHIELD TEMP CONTROLLERS REQUIRED. REF AMM 30-41-01-710-801. OPS TEST GOOD IAW AMM 30-41-01-710-801. (SDR CLOSED)