As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CARGO FLOORBEAM AT FS 621.00 AND BETWEEN RBL 27-45 CORRODED. BLENDED CORROSSION IAW SRM 51-21-06. ORIGINAL MATERIAL .093 MINIMUM REMAINING MATERIAL IS .089 FOUND TO BE IN LIMITS REF SRM 53-00-00. RESTORED FINISH TO AREA REF SRM 51-21-16.