What was found
DURING ROUTINE SCHEDULED MX, FOUND THE EMERGENCY EXIT LIGHTS ON MAIN CABIN DOOR, COCKPIT CEILING AND STEP, AND GALLEY EXIT SIGN WOULD NOT ILLUMINATE. MX R & R NR 1 EMERGENCY LIGHT POWER SUPPLY AND BATTERY ALONG WITH NR 2 EMERGENCY LIGHT BATTERY IAW AMM 33-50-04 WITH OPS CHECKS SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.