What was found
PAX CABIN LEFT SILL HAS MINOR CORROSION ON NUTPLATE AT FS 559.0. REMOVED NUTPLATE IAW SRM 51-42-02. REMOVED CORROSION IAW SRM 51-21-06. PERFORMED UT THICKNESS INSPECTION OF BLEND AREA IAW MAC NDT PROCEDURE UT-3. MIN MATERIAL REMAINING IS .039" ORIGINAL .050" MATERIAL REMOVED IS .011". AREA EXCEEDS LIMITS IAW SRM 53-00-00. REPLACED STRAP WITH NEW STRAP IAW SRM 51-42-06. CLASSIFIED AS MAJOR.