Service difficulty report · Floor Panel · Cndair CL6002B19

Difficulty date
March 5, 2012
Submitted
March 8, 2012
Operation
Air carrier
Aircraft
N857AS
Make and model
Cndair CL6002B19
Aircraft serial
7411
Aircraft time
27,170 hours, 24,022 cycles
Part
Floor Panel
Condition
Corroded
Location
Bs 529
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CABIN AREA PRESSURE FLOOR CORRODED AT FS 529.00 AND BETWEEN LBL 36 TO STR 18 2EA PLACES. BLENDED CORROSION IAW SRM 51-21-06. PERFROMED UT THICKNESS INSPECTION OF BLENDED AREAS IAW MAC NDT PROCEDURE UT-3. MINIMUM MATERIAL REMAINING .072", ORIGINAL IS .080", MATERIAL REMOVED IS .008" MIN MATERIAL REMAINING ON CHEM MIL .053" ORIGNAL .055", MATERIAL REMOVED IS .002" MIN MATERIAL REMAINING .067", ORIGINAL .080" MATERIAL REMOVED .013" BLENDED AREAS WITHIN LIMITS IAW REO 601R-53-41-666, TABLE 14, TABLE 2.