What was found
EMERGENCY EXIT FLOOR FLOODLIGHT AT PAX DOOR IS INOPERATIVE. R & R NR 2 BATTERY PACK CHARGER IAW AMM 33-51-17 AND AIPC 33-51-17, ITEM 8. PERFORMED OP TEST OF EMERGENCY LIGHTS IAW AMM 33-51-15-710-801. NO FAULTS FOUND AT THIS TIME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EXIT FLOOR FLOODLIGHT AT PAX DOOR IS INOPERATIVE. R & R NR 2 BATTERY PACK CHARGER IAW AMM 33-51-17 AND AIPC 33-51-17, ITEM 8. PERFORMED OP TEST OF EMERGENCY LIGHTS IAW AMM 33-51-15-710-801. NO FAULTS FOUND AT THIS TIME.