What was found
FOUR CORRODED "L" ANGLES FOUND TO BE CORRODED AT HINGE SIDE OF PAX DOOR. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. PERFORMED UT THICKNESSS INSPECTION OF BLEND AREA IAW MAC NDT INSP PROCEDURE UT-3. NO INDICATIONS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUR CORRODED "L" ANGLES FOUND TO BE CORRODED AT HINGE SIDE OF PAX DOOR. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. PERFORMED UT THICKNESSS INSPECTION OF BLEND AREA IAW MAC NDT INSP PROCEDURE UT-3. NO INDICATIONS NOTED.