What was found
CARGO BAY RT LOWER WALL PANEL 282ARW DAMAGED AT AFT LOWER SECTION. PICK UP FASTENER HOLES WHEN REQUESTED. DRILLED ALL REQUIRED FASTENER HOLES AS REQUIRED IAW SRM 51-40-11. THIS REPAIR REQUIRES MAJOR/MINOR CLASSIFICATION IAW ASA SOP 572. THE REPAIR IS CLASSIFIIED AS A MAJOR REPAIR IAW ASA SOP 5702. REPLACE/INSTALL NEW PANEL. REPAIRED WITH SERVICABLE PANEL 282ARW REFER TO JOB 8741740, OPS 2002&7002 FOR REMOVAL AND INSTALLATION. COMPLIED WITH EO 600-25-0279. RII FOUND TO BE SATISFACTORY. (SDR CLOSED)