What was found
SERVICE DOOR FLOOR SUPPORT ANGLE CORRODED AT 314.00 AND RBL 40. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-00. INSTALLED SERVICEABLE ANGLE IAW DWG 601R38303, REV AR AND SRM 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR FLOOR SUPPORT ANGLE CORRODED AT 314.00 AND RBL 40. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-00. INSTALLED SERVICEABLE ANGLE IAW DWG 601R38303, REV AR AND SRM 51-42-21.