What was found
SERVICE DOOR LOWER SILL ANGLE HAS MULTIPLE AREAS OF CORROSION FROM FS 319.00 THROUGH 349.00. REMOVED SILL IAW SRM 51-42-21. FABRICATED AND INSTALLED SILL ANGLE IAW DWG NR 601R38303. REPAIR CLASSIFIED AS MINOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR LOWER SILL ANGLE HAS MULTIPLE AREAS OF CORROSION FROM FS 319.00 THROUGH 349.00. REMOVED SILL IAW SRM 51-42-21. FABRICATED AND INSTALLED SILL ANGLE IAW DWG NR 601R38303. REPAIR CLASSIFIED AS MINOR.