What was found
DURING C-CHECK LAV CENTER OMEGA BEAM BUTTSTRAP CORRODED (LEVEL 1 LOCAL) AROUND NUTPLATE AT FRAME 59. MX R & R LAV CENTER OMEGA BEAM BUTTSTRAP AT FRAME 59 IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK LAV CENTER OMEGA BEAM BUTTSTRAP CORRODED (LEVEL 1 LOCAL) AROUND NUTPLATE AT FRAME 59. MX R & R LAV CENTER OMEGA BEAM BUTTSTRAP AT FRAME 59 IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.