What was found
FOUND THE RT FLOOR SILL TO HAVE ONE AREA OF CORROSION AT 559+30 TO 559+84 .4" X 1" X .015" DEEP. FOUND DAMAGE BEYOND REPAIRABLE LIMITS. REPAIRED IAW REO 601R-53-51-194.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND THE RT FLOOR SILL TO HAVE ONE AREA OF CORROSION AT 559+30 TO 559+84 .4" X 1" X .015" DEEP. FOUND DAMAGE BEYOND REPAIRABLE LIMITS. REPAIRED IAW REO 601R-53-51-194.